EP-FXT Science Data Center / Users Guide v2.0 · 2026-11-04

FXTSoft v2.0 documentation

fxtparticleidentify help

Command help for fxtparticleidentify in the FXTSoft v2.0 release.

← Back to Command Reference

NAME

fxtparticleidentify-- Identification of particle candidates

USAGE

fxtparticleidentify evtfile outfile

DESCRIPTION

fxtparticleidentify identifies and removes particle-induced tracks, showers, and instrumental-effect events. Set both xlength and ylength to 11 for FF/PW data or 35 for TM data.

PARAMETERS

evtfile [file name]
Name of the input calibration event FITS file.

outfile [file name]
Name of output event FITS file.

particlefile [file name]
Name of the output particle-induced Event FITS File (DEFAULT=NONE, no output file)

bkgnum[integer]
Background threshold (DEFAULT=5).

efrac[real]
Minimum fraction of High Energy particles (>12keV) to all (DEFAULT=0.3)

xlength[integer]
Minimum length along X caused by instrumental effect(11 for FF and PW; 35 for TM)

ylength[integer]
Minimum length along Y caused by instrumental effect(11 for FF and PW; 35 for TM)

(history=yes) [boolean]
If set to yes, write parameter values and other information in HISTORY blocks (DEFAULT=yes).

(clobber) [boolean]
If 'clobber'=yes and outfile=filename, the file with the same name will be overwritten, if it exists (DEFAULT=yes).

(chatter) [integer]
Chatter Level (min=0, max=5) (DEFAULT=1).

EXAMPLES

  1. general usage

     FF/PW modes >fxtparticleidentify evtfile=13600002613/fxt/event/fxt_b_13600002613_pi.fits outfile=fxt_b_13600002613_cleanpi.fits xlength=11 ylength=11
        
     TM mode  >fxtparticleidentify evtfile=13600002613/fxt/event/fxt_a_13600002613_tmpi.fits outfile=fxt_a_13600002613_cleanpi.fits xlength=35 ylength=35
    

BUGS

SEE ALSO

Manual page updated

2026-11-04

Original help author: Zhao Haisheng